- SF-401PLUS | SURECOM
SF-401PLUS Introduction: The frequency meter capable of measuring the parameters of the frequency of the continuous carrier signal walkie-talkies , with signal strength indicator. it is the tool of choice for maintenance personnel ,test frequency and signal strength of wireless enthusiasts. This portable frequency counter is designed for counting continuous wave signal comes from Two-way Radio. There are easy ranges for you to choose. The ranges cover most of the frequency of the two way radios you want to measure. Its four-button control is easy to use and its small size allows you to carry it anywhere you like. Work by TCXO(Temperature Compensate X'tal (crystal) Oscillator) ,In the range of -45 ℃ ~ 65 ℃ can reach ± 2 ~ ± 4ppm accuracy This include very interesting frequency areas such as 2m HAM radio, all VHF and UHF DMR Radio signal e frequency counter. Easy Battery level digital mode for DMR radio only, not for other digital device Feature & Specification: Frequency range: 27Mhz-3000Mhz ! Note: (27MHz to 100MHz It can not be guaranteed and the corresponding normal emission appliance) CTCSS/DCS Decoder (must be 136-174/400-520MHz) Frequency counter for DMR radio Frequency digital 0.000 or 0.0000 ( +-0.001) Work by TCXO( Temperature Compensate X'tal (crystal) Oscillator) 2~2.5ppm Frequency Response time: 0.2-0.5sec.( CTCSS/CDCSS >0.5-1sec) TFT Color Display 240 x 320 ,LCD Dim level setting Build-in Li-ion battery Net Weight: 113g 4 buttons control Auto power off 1-9minutes Charging battery LED indicator Manual Wholesale Quotation Shopping Power On/Off Power On –Press and Hold down the [black key] by 2 second Power Off –Press and Hold down the [black key] by 4 second of number count down to 0 Charging the battery Plug the Power cord into adaptor , Micro USB connected SF-401, The Led indicating: *The RED Led is light - Charging * The Green Led is light - Full How to check Frequency measuring. See PIC.3 The transmitter near the frequency counter antenna , see the signal reception conditions is zone green, you can test. Please see Pic.3 cautions: e.g. display 1800.000Mhz , The transmitter distance is too close to the frequency counter will affect the test results, , the signal bar is red .(see Pic.1) e.g. display 0.000, , The transmitter distance is too far to the frequency counter and signal is weak ,will affect the test results, the signal bar is low .(see Pic.1) ! Note: (27MHz to 100MHz It can not be guaranteed and the corresponding normal emission appliance) . How to check Frequency of Digital DMR Radio Press[ F3 Digital] from Measuring screen mode See PIC.1 Note: Use Digital mode have 3 Decimal only MENU funtion setting and save. See PIC.4 Press [F1] > into menu Page Press [F3 down] or [F4 Up] into System and Press [F2 Rtn] into system Page PIC.4 Press[F3 down] or [F4 Up] select funtion ,Press [F2 Edit] > [F3 - ][F4 +] change mode Press[Menu] > [F1 ]to Exit or [F4 ] to Save and Exit Menu Setting Rf defect level: The smaller the rf detect level, the more sensitive How to check CTCSS/DCS code 1.Radio must be 136-174/400-520MHz 2.Radio must be ANALOG Package Contents 1x SF401 PLUS Frequency Counter 1x UHF Antenna 1x English User Manual 1x USB charger cable 1x USB AC adapter 100-240V If you have related videos, please share with us, please contact us
- Q&A_SW111_SW114 | SURECOM
Q1) Very high calibrate and not accurate when I transmitte to my UHF radio base to SW-111 A1) The frequency of SW-111 is 27MHz, it not for VHF UHF radio Q2) Can I plug in a SMA cable on SW-111? A2) the Antenna & TRANS connector of SW-111 is SO239, if you want to connect with a SMA cable, you need to add an adaptor Q3) Hi SW-114 can detect SWR and watt without cable? A3) No, without cable, you can only measure the electric field strength. If you want to measure SWR, you must have a cable. Q4) The Surecom 111 power meter needs more instructions. What do each of the numbers on the screen mean? I need to know if my power is 5, 10, 20, 30, 40, 50, 60 watts? A4) The numbers 0, 1, 2, 4, 6, 8, and 10 on the display are for checking 10W of power. If you want to check 100W of power, simply multiply the numbers by 10. For example, 1=10, 2=20, 4=40 Q5) Do I need to buy a jumper cable for SW111 / SW114? A5) SW-111 / SW-114 do not include any connecting cable, therefore you need to buy it Q6) Can this be permanently left attached to the CB cable without affecting the signal? A6) We don't suggest for long-term connection, because long-term connection may cause deviations in SWR or power readings, especially under high power or high frequency environments. Regular calibration or temporary removal of the test is recommended.
- Product Catalog | SURECOM
Surecom Radio equipment company, we product the radio product. ALL PRODUCT CATALOG ANTENNA ANALYZER An antena analyzer ' (also known as a noise bridge, RX bridge, SWR analyzer, or RF analyzer) is a device used for measuring the input impedance of antenna systems in radio electronics applications. MODEL: SA160 SA250 SA350 MINI1300 Read More FREQUENCY COUNTER A frequency counter is an electronic instrument, or component of one, that is used for measuring frequency. Frequency counters usually measure the number of cycles of oscillation, or pulses per second in a periodic electronic signal. Such an instrument is sometimes referred to as a cymometer. Model: SF401 SF103 Read More FIELD STRENGTH METER Field strength meter is actually a simple receiver. The RF signal is detected and fed to a microammeter, which is scaled in %. The frequency range of the tuner is usually within the terrestrial broadcasting bands. Model: SS10 SS11 Read More REPEATER CONTROLLER A repeater is an automatic radio-relay station, usually located on a mountain top, tall building, or radio tower. It allows communication between two or more bases, mobile or portable stations that are unable to communicate directly with each other due to distance or obstructions between them. Model: SR112 SR328 SR628 SR629 Read More V.S.W.R. POWER METER The standing wave ratio meter, SWR meter, ISWR meter (current "I" SWR), or VSWR meter (voltage SWR) measures the standing wave ratio (SWR) in a transmission line.[a] The meter indirectly measures the degree of mismatch between a transmission line and its load (usually an antenna). Electronics technicians use it to adjust radio transmitters and their antennas and feedlines to be impedance matched so they work together properly, and evaluate the effectiveness of other impedance matching efforts. Model: SW102VU-S, SW102VU-N SW102HF SW33 ,SW33MARKII ,SW33PLUS SF20 SW-111 SW-114 Read More CB-RADIO 27MHZ 40 CH CB radio MODEL: CB-9250 CB27 Read More Antenna Accessory Reliable, High Performance For Any Antenna Application SURECOM antenna accessories are the world standard for reliable, high performance communication parts. Broad portfolio of standard, high performance and shock resistant mobile mounts. Antenna Adaptor Balun Read More MOBILE RADIO An antena analyzer ' (also known as a noise bridge, RX bridge, SWR analyzer, or RF analyzer) is a device used for measuring the input impedance of antenna systems in radio electronics applications. MODEL: S-KT-8900 Quad Band S-KT-7900 Dual BAND S-980PLUS Read More BT-Speaker Mic One of the important features of a Bluetooth speaker is the built-in mic that can be used for hands-free calling. The speaker is loud enough that you can clearly hear the person on the other end and it releases your hands to do other tasks while calling, Item is suit for walkie-talkie and mobile radio Model: 41-92 41-99 41-101 41-105 Read More POC WALKIE-TALKIE Surecom 4G LTE Network Radio Walkie Talkie Specification: Operating system: Android system Intercom system: 409PTT Working temperature: -30C~+75C Working voltage: 3.4-4.2VDC H5-V8 R7-4G T1Q S808 S1 T3 Z9PLUS Read More WALKIE-TALKIE A walkie-talkie, more formally known as a handheld transceiver , is a hand-held, portable, two-way radio transceiver.we are sell high power and FRS walkie-talkie , The Family Radio Service (FRS) is an improved walkie-talkie radio system authorized in the United States since 1996. , and 2003 in HONGKONG , This personal radio service uses ... SJ-688HP VHF/UHF 10-12W S-8R 4 BAND TX SJ409 FRS RADIO S-UV5R waterproof Read More
- SW-102HF | SURECOM
V.S.W.R. meter Introduction V.S.W.R. Forward and reflected power direct digital readout, without any calibration. Maximum measurable power range up to 120W. low insertion loss (0.3 decibels or less) structure allows it to be permanently connected. All Function display ( S.W.R, F.W, R.W,Battery Level) SW-102HF 1.5-70MHz V.S.W.R. meter Introduction V.S.W.R. Forward and reflected power direct digital readout, without any calibration. Maximum measurable power range up to 120W. low insertion loss (0.3 decibels or less) structure allows it to be permanently connected. All Function display ( S.W.R, F.W, R.W,Battery Level) Feature & Specification Frequency range: 1.5-70MHz Measurable power range: 0.5 - 120W Measurable S.W.R range: 1.00:1~19.99:1 Maximum power: 120W Impedance: 50Ω Size: W 76 X H 77 X D35 mm. Weight: < 220 grams Battery : 3.7V Li-ion Rechargeable Battery Interface: SO236(SL16) Manual Wholesale Quotation Shopping Interface: SO239 MAX. Power in :120 W V.S.W.R1.00 :1 ~ 19.99:1 Frequency Range COVER : 1.5MHz-70MHz Insertion Loss< 0.15dB(VHF) , < 0.25dB(UHF) Temperature 0℃~60℃ Battery Level Display : Yes Battery Build-in :3.7V Li-ion Battery Auto Power Off : 1-9 mins Size: 76*77*35 (mm) Charger in 5V (micro usb) Back-light AUTO OFF Interface (in and out ) SO239 (SL16) Weight: 220g (include battery) Power ON/OFF: Press [Red button] 2 second to power on or power off MENU Display Content 1 LCD (Back Light off Time)0-9 , "0" is always on, 1 min to 9 mins 2 POWER OFF 0-9 "0" is always on, 1 min to 9 mins 3 Adjustment Forward Power -99 to +99 Fine Tune Level % * Supplier, the product will add functionality without having to give notice Set & Save: Press MENU [Blue button] Press F1 [Red button)(Select 1-3 Function) Press [Blue button] ( - ), [Yellow button] (+) Press the [Red button ]for 2 seconds Press the [Blue button] to SAVE and EXIT How to Connect your Radio : TX : Connect to RADIO RF Output ANT : Connect to ANTENNA or 50 OHM Dummy Load ( Proper adaptor/cable is required if .your device has different type of connectors.) How to charge your meter : Connect external USB DC+5V source (e.g. USB charger) to micro USB input When display is showing 'E', it means the unit is powered by USB. When display is showing 'B', it means the unit is powered by internal battery. How to use a swr meter to test antenna (SWR) : (pic 1) Measurement V.S.W.R. : 1)Radio RF output connect to meter "TX" socket . 2)Antenna connect to meter "ANT" socket . 3)Push TX PTT from Radio, METER display is SWR measure data. How to use a meter to test the output Watt of your transceiver : Measurement Power: 1)Radio RF output connect to meter "TX" socket . 2)50 Ohm Dummy connect to meter "ANT" socket . 3)Push TX PTT from Radio, METER display is Power measure data . How to rotate the display: Press Yellow button and hold to rotate display in 180 degree Package Contents 1x SURECOM SW-102-HF 1x Power PSU 100-240V 1x Charger Cable 1x English Users Manual N - CONNECTOR MODEL FREQ. RANGE CONNECTOR FREQUENCY COUNTER DMR SW-102HF 1.5MHz -70MHz SO239(SL16) NO NO SW-102-UV 125MHz -525MHz SO239(SL16) /N YES NO SW-102D-UV 125MHz-525MHz SO239(SL16) / N YES YES If you have related videos, please share with us, please contact us
- SW-32 | SURECOM SWR / Power METER
V.S.W.R. meter Introduction VSWR. Forward and reflected power direct digital readout, without any calibration. Maximum measurable power range up to 120W. low insertion loss (0.3 decibels or less) structure allows it to be permanently connected. Build in Frequency counter . All Funtion display ( Frequency Counter ,Powe SW-32UV 125-525MHz SW-32HF 1.8-60MHz SWR & Power Meter This SWR & Power meter is a highly accurate RF meter for measuring Forward Power,Reflected Power, and VSWR. Main Features: · Large meter display for easy reading. · Forward RF power readings, switchable to indicate either average power · Reflected RF power readings. · VSWR ratios. · Convenient control for easy operation. Manual Wholesale Quotation Shopping SURECOM SW-32 SWR & Power Meter Instruction Explanation of Features: 1.Meter Display: I ndicates Forward/Reflected Power in Watts and SWR ratio 2.Meter Zero adjust: Mechanical zero adjustment for meter needle 3.Range Switch: Selects RF Power Ranges of 10W and 100W 4. Blue Switch 1: Selects POWER , SWR 5.Red Switch 2: POWER of (REF/ FWD) , SWR of (set SWR / SWR) 6.SWR SET Control Knob: Sets full scale deflection when measuring VSWR. 7.ANT Connector : Coax connector to 50 Ohm antenna system. 8.TX Connector : Coax connector to transmitter 50 Ohm RF output. FORWARD POWER MEASUREMENT 1. Set the Blue botton to the ‘POWER’ position. Set the Red botton ,‘FWD’ position. 2. Set the Radio transceiver to transmit and read the scale corresponding to the Power range selected yellow botton (10W, or 100W) REFLECTED POWER MEASUREMENT 1. Set the Blue botton switch to the ‘POWER’ position. Set the Red botton ,‘REW’ position. 2. Set the radio transceiver to transmit and read the scale orresponding to the Power range selected (10W, or 100W) VSWR MEASUREMENT Step 1 1. Set the Blue botton switch to the ‘SWR set’ position.Set the Red switch to the ‘SET SWR’ position. 2. Set the radio transceiver to transmit mode. 3. Slowly turn the CAL Control Knob clockwise until the meter point is at the ‘ CAL ’ position. This should be full scale. Step 2 Set the Red botton switch to the ‘SWR’ position while transmitting. The meter will now indicate the SWR ratio. CAUTION 1. Since the meter movement is very sensitive, avoid excessive vibration or mechanical shock to the unit. 2. The absolute maximumpower that should be applied to the meter is 100W. Also observe maximumpower inputs of 10W when unsing the lower ranges. 3. The transceiver and antenna connections to the meter must never be reversed.Always observe the correct connections to the transmitter and the antenna as 4. The meter has been carefully calibrated at the factory. Tampering with any of the internal circuitry or sensors may cause damage and will degrade the accuracy of the meter. 5. Do not expose the meter to excessive temperatures, high humidity, or strong magnetic fields. If you have related videos, please share with us, please contact us
- Order Online | SURECOM
Order Online From Online Dealers 28 BEDFORD AVE, BROOKLYN, NY 12345 2 BEDROOMS $930,000 20 S 9TH ST, BROOKLYN, NY 12345 2 BEDROOMS $750,000 72 MARCY AVE, BROOKLYN, NY 12345 4 BEDROOMS $700,000 Profile Pic Candidate Applied # of Positions Email Robert Zanny 12/16 2 robert@gmail.com Dana Marks 09/16 1 dana@gmail.com Robert Zanny 10/15 3 betty@gmail.com
- Automatic Thermometer | SURECOM
Automatic Thermometer non-contact infrared automatic thermometer 0032-0017 SURECOM non-contact infrared automatic thermometer Model / Brand:0032-0017 (3217) SURECOM Accuracy:+-0.2degree Response time:0.1-0.5s Abrormal automatic alarm:flashing +"Di Di"Sound Charging methord:USB charging or Battery Automatic measurement:Measuring Distance 5-10cm Input:usb MiRICO USB DC5v Dimensions:170*115*140 weight:350g Install method:Nail hook, double sided adhesive sticking, bracket fixing Read More 0032-0038 SURECOM non-contact infrared automatic thermometer Model / Brand:0032-0038 (3238) SURECOM Accuracy:+-0.2degree Response time:0.5s Abrormal automatic alarm:flashing +"Di Di"Sound Charging methord:USB charging or Battery Automatic measurement:Measuring Distance 5-10cm Input:usb DC5v Dimensions:170*115*140 weight:350g Install method:Nail hook, double sided adhesive sticking, bracket fixing Read More